{"id":3660,"date":"2022-01-19T16:29:27","date_gmt":"2022-01-19T15:29:27","guid":{"rendered":"https:\/\/levibio.it\/?post_type=avada_portfolio&#038;p=3660"},"modified":"2024-10-31T10:20:59","modified_gmt":"2024-10-31T09:20:59","slug":"haart-300-200","status":"publish","type":"avada_portfolio","link":"https:\/\/levibio.it\/en\/Prodotti\/haart-300-200\/","title":{"rendered":"HAART 300 and HAART 200"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first\" style=\"--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-1\"><p><strong>HAART 300<\/strong> and <strong>HAART 200<\/strong> are aortic anuloplasty devices designed specifically for tricuspid aortic valve repair, HAART 300, and bicuspid aortic valve repair, HAART 200.<\/p>\n<p>The devices were developed for correction of annular dilatation and\/or maintenance of annular aortic valve geometry in adult patients undergoing <strong>tricuspid and bicuspid aortic valve<\/strong> repair.<\/p>\n<p>HAART technology reduces annular dilation and reorients the two flaps into a semicircular configuration. This orientation helps to establish an effective coaptation geometry by simplifying the flap repair procedures required to restore valve competence.<\/p>\n<p>&#8211; Reshapes the aortic annulus;<\/p>\n<p>&#8211; Reduces the circumference of the dilated annulus to restore the annulus to its physiological diameter;<\/p>\n<p>&#8211; Provides support for the aortic wall;<\/p>\n<p>&#8211; Ensures adequate coaptation of the valve leaflets;<\/p>\n<p>&#8211; Allows for easier valve repair, including root replacement\/valve-sparing operations.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-last\" style=\"--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-video fusion-youtube fusion-aligncenter\" style=\"--awb-max-width:600px;--awb-max-height:360px;--awb-width:100%;\"><div class=\"video-shortcode\"><div class=\"fluid-width-video-wrapper\" style=\"padding-top:60%;\" ><iframe title=\"YouTube video player 1\" src=\"https:\/\/www.youtube.com\/embed\/Js6pxOlyVxA?wmode=transparent&autoplay=0\" width=\"600\" height=\"360\" allowfullscreen allow=\"autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture;\"><\/iframe><\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element awb-imageframe-style awb-imageframe-style-below awb-imageframe-style-1 in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h4_typography-font-family);--awb-caption-title-font-weight:var(--h4_typography-font-weight);--awb-caption-title-font-style:var(--h4_typography-font-style);--awb-caption-title-size:var(--h4_typography-font-size);--awb-caption-title-transform:var(--h4_typography-text-transform);--awb-caption-title-line-height:var(--h4_typography-line-height);--awb-caption-title-letter-spacing:var(--h4_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"400\" height=\"400\" title=\"HAART 300\" src=\"https:\/\/www.levibio.it\/wp-content\/uploads\/2022\/01\/HAART-300-e1673607932449.png\" alt class=\"img-responsive wp-image-4458\" srcset=\"https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/HAART-300-e1673607932449-200x200.png 200w, https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/HAART-300-e1673607932449.png 400w\" sizes=\"(max-width: 800px) 100vw, 600px\" \/><\/span><div class=\"awb-imageframe-caption-container\"><div class=\"awb-imageframe-caption\"><h4 class=\"awb-imageframe-caption-title\">HAART 300<\/h4><\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element awb-imageframe-style awb-imageframe-style-below awb-imageframe-style-2 in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h4_typography-font-family);--awb-caption-title-font-weight:var(--h4_typography-font-weight);--awb-caption-title-font-style:var(--h4_typography-font-style);--awb-caption-title-size:var(--h4_typography-font-size);--awb-caption-title-transform:var(--h4_typography-text-transform);--awb-caption-title-line-height:var(--h4_typography-line-height);--awb-caption-title-letter-spacing:var(--h4_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"400\" height=\"400\" title=\"HAART 200\" src=\"https:\/\/www.levibio.it\/wp-content\/uploads\/2022\/01\/HAART-200-e1673607969380.png\" alt class=\"img-responsive wp-image-4456\" srcset=\"https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/HAART-200-e1673607969380-200x200.png 200w, https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/HAART-200-e1673607969380.png 400w\" sizes=\"(max-width: 800px) 100vw, 600px\" \/><\/span><div class=\"awb-imageframe-caption-container\"><div class=\"awb-imageframe-caption\"><h4 class=\"awb-imageframe-caption-title\">HAART 200<\/h4><\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-2\"><p>The healthy human aortic valve regulates flow from the left ventricle of the heart to the body during systole via full opening of the valve leaflets. During diastole, the valve leaflets close to eliminate or minimize blood flow backward through the valve into the left ventricle.<\/p>\n<p>Some patients suffer from dilation of the aortic valve annulus and aortic wall allowing blood to flow back into the ventricle resulting in AI.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last fusion-column-inner-bg-wrapper\" style=\"--awb-inner-bg-size:cover;\"><span class=\"fusion-column-inner-bg hover-type-none\"><a class=\"fusion-column-anchor\" href=\"https:\/\/www.levibio.it\/wp-content\/uploads\/2023\/01\/Depliant-Haart-200-e-Haart-300.pdf\"><span class=\"fusion-column-inner-bg-image\"><\/span><\/a><\/span><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-button-wrapper fusion-aligncenter\"><a class=\"fusion-button button-flat button-xlarge button-default fusion-button-default button-1 fusion-button-default-span fusion-button-default-type\" style=\"--button-border-radius-top-left:0px;--button-border-radius-top-right:0px;--button-border-radius-bottom-right:0px;--button-border-radius-bottom-left:0px;\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/levibio.it\/levibiotech\/wp-content\/uploads\/sites\/2\/2017\/12\/Brochure-BioStable-1.pdf\"><span class=\"fusion-button-icon-divider button-icon-divider-left\"><i class=\" fa fa-book awb-button__icon awb-button__icon--default\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-button-text awb-button__text awb-button__text--default fusion-button-text-left\">Scarica la brochure<\/span><\/a><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:50px;--awb-margin-bottom:0px;--awb-background-color:#3781b2;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-padding-top:50px;--awb-padding-bottom:50px;--awb-bg-size:cover;--awb-margin-top:30px;--awb-margin-bottom:30px;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-3\"><h2 class=\"entry-title\"><span style=\"color: #ffffff;\">HAART 300 DESIGN<\/span><\/h2>\n<p><span style=\"color: #ffffff;\">The HAART 300 ring design was developed from high-resolution CT angiographic studies of 10 normal human aortic valves. The design process is depicted below. All views are in the same orientation.<\/span><\/p>\n<p><span style=\"color: #ffffff;\"><strong>Panel A<\/strong>: High resolution 1 mm thick axial slices of the entire valve were analyzed to assess the anatomy of sinus-leaflet complexes for the right coronary cusp (green), left coronary cusp (orange), and non-coronary cusp (yellow). The structure of each leaflet-sinus complex was defined by maximal numbers of points in Mathematica, and subcommissural areas were marked by red points.<\/span><\/p>\n<p><span style=\"color: #ffffff;\"><strong>Panel B<\/strong>: After incorporating all vertical slices, the subcommissural and annular regions appeared as a 3-pointed coronet with highly elliptical base geometry and outwardly flaring subcommissural posts.<\/span><\/p>\n<p><span style=\"color: #ffffff;\"><strong>Panel C<\/strong>: A representative study shows the elliptical valve base geometry and flaring posts, with a 5-8\u00ba outward flare (tops of all 3 commissures are shown as green circles). The flare was always similar for the 3 posts, and average circumferential lengths between commissures were statistically equivalent. The post of the non-coronary \/ left coronary commissure was always located at the posterior minor axis diameter \u2013 circumference intersection (also the center of the anterior mitral leaflet), with the right coronary cusp centered opposite.<\/span><\/p>\n<p><span style=\"color: #ffffff;\"><strong>Panel D<\/strong>: The final design of HAART ring was based on the average geometry of the 10 normal human valves, with an elliptical 2:3 minor-major diameter base geometry and 10\u00ba outwardly flaring posts. 2:25 \u2013 In addition a HAART 200 Bicuspid ring has been developed for patients with congenital bicuspid valves, or valves where 2 of the 3 leaflets have fused and the valves demonstrate AI. A sizer designed specifically for use in bicuspid patients measures the leaflet free edge length of the larger leaflet or the two fused leaflets. The appropriately sized HAART 200 ring is implanted in the same procedure as described for the HAART 300 tricuspid device. For bicuspid leaflets that are not a 50\/50 valve diameter split, additional leaflet surgical procedures are conducted to reconfigure the valve with two equally sized leaflets. Once the ring is in place and the appropriate leaflet alignment is established the valve once again is competent with no regurgitation.<\/span><\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:50px;--awb-padding-bottom:50px;--awb-margin-top:0px;--awb-background-color:#e8e8e8;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-first\" style=\"--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-4\"><p>Corcym is developing innovative new products for the treatment of cardiovascular disease. Corcym is led by an experienced group of industry executives with expertise in rapid and effective medical device development.<span id=\"more-138\"><\/span><\/p>\n<\/div><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"2446\" height=\"806\" title=\"logo\" src=\"https:\/\/www.levibio.it\/wp-content\/uploads\/2022\/01\/logo.png\" alt class=\"img-responsive wp-image-4636\" srcset=\"https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/logo-200x66.png 200w, https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/logo-400x132.png 400w, https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/logo-600x198.png 600w, https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/logo-800x264.png 800w, https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/logo-1200x395.png 1200w, https:\/\/levibio.it\/wp-content\/uploads\/2022\/01\/logo.png 2446w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":4,"featured_media":3665,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"footnotes":""},"portfolio_category":[80,95],"portfolio_skills":[],"portfolio_tags":[],"class_list":["post-3660","avada_portfolio","type-avada_portfolio","status-publish","format-standard","has-post-thumbnail","hentry","portfolio_category-cardiochirurgia-en","portfolio_category-pediatric-cardiac-surgery"],"_links":{"self":[{"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/avada_portfolio\/3660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/avada_portfolio"}],"about":[{"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/types\/avada_portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/comments?post=3660"}],"version-history":[{"count":9,"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/avada_portfolio\/3660\/revisions"}],"predecessor-version":[{"id":4826,"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/avada_portfolio\/3660\/revisions\/4826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/media\/3665"}],"wp:attachment":[{"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/media?parent=3660"}],"wp:term":[{"taxonomy":"portfolio_category","embeddable":true,"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/portfolio_category?post=3660"},{"taxonomy":"portfolio_skills","embeddable":true,"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/portfolio_skills?post=3660"},{"taxonomy":"portfolio_tags","embeddable":true,"href":"https:\/\/levibio.it\/en\/wp-json\/wp\/v2\/portfolio_tags?post=3660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}